MPO MTP Patch Cord Test Methods

Posted on 15th Sep 2017 @ 6:15 PM

   MPO_MTP_test_method_2.png  MPO_MTP_test_method_-1.jpg

Testing methods:

Method A - using two MPO / MTP Fiber jumpers and a connector (consider a direction, as shown in the upper half portion of the following picture ) to set the reference value . After setting the reference value, then the link to be tested come in (the lower half  portion of the following picture) and to be tested.

MPO_MTP_test_method_3.jpg

Method A test results for each direction including the loss of the fiber and the connector ;Therefore , method A is  used to test such  fiber link: a fiber link with a connector at one end and the other end does not.

Method B - only using one  MPO/MTP fiber optic patch cord (consider a direction, as shown in the upper half portion of the following picture )to set the reference value .After setting the reference value , then the link to be tested come in (the lower half  portion of the following picture ) and to be tested.

MPO_MTP_test_method_4.png

Method B test results including both ends loss of the fiber link and connection . Thus, Method B is used to test such fiber optic link: both ends of the link are with connector, which connectors loss is an important part of the entire loss.

Method C - using three optical fiber patch cords  and two connectors (one-way)and the length between the two fiber optic patch cords are less than 1Meter; to set a reference value ;using the fiber link being tested to replace the fiber optic patch cords between the connectors  when testing the link.

MPO_MTP_test_method_5.png

Thus , Method C test results just including the fiber loss ,not including the loss of the both two ends .

Matters needing attention

1. Firstly, ensuring  the  testing patch cords and being tested patch cords connectors end faces are clean;

2.  Ensuring the testing patch cord  and the being tested patch cord are made and female separately , MPO / MTP patch cords are male connectors with female connectors  during the testing and operation; 

3. As the MPO / MTP patch cords are with A, B, C  polarity distinction, please pay attention to select the appropriate test line when testing the link.

4. The test equipment must be carried out with a multi-channel multi-function devices.

Shenzhen JFOPT  always updates product information on website, welcome  to browse  our website. If you have any questions, please do not hesitate to contact our sales team, they will reply to you within 24 hours, our e-mail address : market@jfopt.com, sales@jfopt.com, market@jfiberoptic.com, market@jfcable.com .